Flow sight glass type 550 PN 10/40 - DIN 11869 (formerly DIN 3237)
Collapse
A stainless steel industrial valve with flanged ends and bolts, featuring a transparent window for visibility inside.
Stainless steel pipe fitting with flanges and threaded connections.
Metal flange pipe fitting with a circular opening and bolt holes for secure attachment.
Stainless steel flanged sight glass with bolted circular viewing port
Flanged stainless-steel pipe section with bolted circular sight glass
Video | Flow sight glass Type 550 – ACI Industriearmaturen GmbH

Flow sight glass type 550 PN 10/40 - DIN 11869 (formerly DIN 3237)

With flange connections according to DIN 1092-1

Google reviews for aci24.com
Available from stock

Flow sight glass PN 10 | PN 16 | PN 25 | PN 40

Configure sight glass

Non binding • Usually a response within 24 hours

Certified quality
Technical data
  • Wiper SGW with PTFE, silicone or EPDM wiper blade
  • LED lamp for Ex and non-Ex areas
  • Spraying device
  • FEP or Halar® coating
  • Mica protection screen
  • PTFE rotor
  • Oil- and grease-free design
  • Silicone-free design including crater test

DN 15 – 50 Square cover flanges
DN 65 – 200 Round cover flanges

Datasheet Info brochure To the Pressure-temperature rating

Flow sight glass Type 550 – ACI Industriearmaturen GmbH

Video | Flow sight glass Type 550 – ACI Industriearmaturen GmbH

Product information

The flow sight glass Type 550 is a robust sight glass fitting based on DIN 11869 (formerly DIN 3237) for the visual monitoring of gaseous or liquid media in pipelines. It is suitable for reliable visual inspection of flow and media condition in industrial processes.

The flow sight glass is designed for installation between DIN/EN flanges and is supplied as standard with flange connections according to DIN EN 1092-1.

The installation position of the flow sight glass Type 550 is freely selectable and can be adapted to the respective installation conditions of the plant.

The design and calculations have been pre-checked by TÜV SÜD Industrie Service GmbH. This enables us to ensure the highest level of safety.

Product overview & technical data

  • Product: Flow sight glass
  • Designation: Type 550
  • Design / connection type: Straight-through design – for installation between DIN/EN flanges, with flange connections
  • Flange connections: according to DIN EN 1092-1
  • Standard: based on DIN 11869 (formerly DIN 3237)
  • Nominal pressure PN: PN 10, PN 16, PN 25, PN 40
  • Nominal sizes DN: DN 15, DN 20, DN 25, DN 32, DN 40, DN 50, DN 65, DN 80, DN 100, DN 125, DN 150, DN 200
  • Version:
    • DN 15 to DN 50: Rectangular cover flanges
    • DN 65 to DN 200: Round cover flanges
  • Temperature:
  • Fitting material: Stainless steel 1.4408
  • Glass: Borosilicate glass according to DIN 7080
  • Options & accessories: SGW wiper, LED light (also available with ATEX approval for potentially explosive atmospheres on request), FEP/Halar® coating, mica protection screen, PTFE rotor, oil- and grease-free version, silicone-free version, LABS-compliant version on request, optional inspections: crater test, radiographic testing, ultrasonic testing

Material selection & options

The flow sight glass Type 550 is manufactured as standard from cast stainless steel 1.4408 and is therefore suitable for corrosion-exposed industrial applications.

On request, the flow sight glass with flange connections is also available in special alloys such as duplex or Alloy C22. This makes the fitting suitable for particularly demanding operating conditions and corrosive media.

Thermally tempered borosilicate glass according to DIN 7080 (MAXOS®) is used as the standard glass material.

For higher thermal loads, the sight glass can additionally be equipped with a mica protection screen. For applications involving aggressive chemicals or alkalis, the sight glass can optionally be equipped with an FEP or Halar® coating.

For sealing, flat gaskets made from different materials are available, e.g. Frenzelit novaphit® MST XP, KlingerSil® C4400, Garlock Gylon® and PTFE (pure or modified). More than 50 additional sealing materials from well-known manufacturers are available on request.

This allows the flow sight glass to be specifically adapted to the medium, temperature, pressure and respective process requirements.

Application areas

The flow sight glass similar to DIN 11869 (formerly DIN 3237) is suitable wherever liquid or gaseous media in pipelines and plants must be safely observed and monitored.

Typical applications include piping systems in the chemical industry, the petrochemical industry, general industry and plant and apparatus engineering. The fitting also provides a reliable solution for other industrial processes in which flow and media condition need to be visually monitored.

Advantages at a glance

  • Reliable visual flow inspection in pipelines and plants
  • Design review by TÜV SÜD
  • Version based on DIN 11869 (formerly DIN 3237)
  • Sight glass with flange connections according to DIN EN 1092-1
  • Available in DN 15 to DN 200
  • Designed for PN 10, PN 16, PN 25, PN 40
  • Suitable for liquid and gaseous media
  • With borosilicate glass according to DIN 7080
  • With metal-fused borosilicate glass according to DIN 7079
  • Body made from corrosion-resistant stainless steel 1.4408
  • Available with various gasket materials, protective coatings and additional equipment
  • Optionally available with wiper, LED light and mica protection screen
A stainless steel industrial valve with flanged ends and bolts, featuring a transparent window for visibility inside.

Cross-section
drawing

Sketch of two flow sight glasses with dimensions
Dimensions
DN 15 20 25 32 40 50 65 80 100 1251 1501 2001

D (PN10)

95 105 115 140 150 165 185 200 220 250 285 340

D (PN16)

95 105 115 140 150 165 185 200 220 250 285 340

D (PN25)

95 105 115 140 150 165 185 200 235 270 300 -

D (PN40)

95 105 115 140 150 165 185 200 235 270 300 -
BL 130 150 160 180 200 230 290 310 350 400 480 600
D1 32 32 48 48 65 80 80 100 125 150 175 175

1) According to DIN 11869

Quick overview

max. 40 barg
-196°C to 400°C
for liquid media
for gaseous media
Nominal sizes
DN 15 - 200
> 50 sealing materials
Accessories available
TÜV pre-tested

FAQs

The installation of the flow sight glass is possible in horizontal and vertical piping runs. The specified flow direction must be strictly observed. A raised direction arrow cast into the housing clearly indicates the permissible flow direction. The operating and installation instructions must be observed before installation.

An indication rotor made of PTFE is particularly suitable for applications where liquids and their flow in the process circuit are visually difficult to detect – for example due to a transparent media color or a lack of turbulence as a natural flow indicator. The indication rotor is intended exclusively for use with liquid media. It is not designed for gaseous media.
In addition, a sufficient flow velocity is required to set the rotor in motion and ensure a reliable flow indication.

Before replacing the sight glass panes, the fitting should be removed from the pipeline to avoid tensile and torsional loads on the line when loosening the connection screws on the cover flange. As a rule, we recommend having the replacement carried out at the factory. If this is not possible on site, please follow our installation and operating instructions. We are available to advise you at any time. After replacement, all media-contacting gaskets as well as the atmosphere-side glass pads must be replaced. Before assembly, ensure that the screws are sufficiently lubricated to prevent seizing. Finally, a tightness test at 1.5 times the nominal pressure must be carried out.

When using borosilicate glass according to DIN 7080, note that unprotected glass is heat-resistant up to a maximum of 280 °C. An additional mica protective screen increases the temperature resistance to up to 300 °C. With thermally untempered borosilicate glass, temperatures of up to 400 °C are possible. In this case, important parameters such as the actual operating pressure should already be specified when requesting a quote.

The use of the Type 550 sight glass is possible without problems down to -196 °C. The correct selection of the material combination is important. The borosilicate glass and the housing are to be used down to -196 °C. In this case, it is important to order a material test certificate W10 according to AD 2000 for the housing and cover flanges. For temperatures ≥ -60 °C, screws A2-70 must be used. In addition, the choice of gasket must be taken into account. Please contact us for advice.

A flow sight glass is installed directly in the pipeline. Through the sight glass you can inspect liquid and gaseous media for cloudiness, discoloration, bubbles or particles and, depending on the medium, observe the flow.

Type 550 and 550V: DN 15 to DN 150 in PN 10, 16, 25 and 40, DN 200 in PN 10 and 16, each with flanges according to DIN EN 1092-1. Type 550A: NPS 1/2" to 8" in Class 150 and 300 according to ASME B16.5.

Type 550 is the standard version for DIN/EN flanges. Type 550V is designed for vacuum down to 2 mbar absolute. Type 550A has flange connections according to ASME B16.5.

With borosilicate glass according to DIN 7080 from −196 °C to +280 °C, with an additional mica protective screen up to 300 °C and with untempered borosilicate glass (Borofloat®) up to 400 °C. Type 550V is rated for −60 °C to +200 °C.

The housing is made of stainless steel casting 1.4408. We select glass and gaskets to suit your media and operating conditions.

Yes. Depending on the version, LED sight glass lights, optionally with ATEX approval, as well as sight glass wipers, spraying devices and mica protective screens are available.

We supply type 550 in DN 15 to DN 100 from stock. Further nominal sizes as well as the 550V and 550A versions are manufactured on request. All flow sight glasses are delivered fully assembled.

The installation is possible in horizontal and vertical piping runs. The flow direction must be strictly observed; a raised arrow on the housing indicates it. Observe the operating and installation instructions before installation.

Before replacing the sight glass panes, the fitting should be removed from the pipeline. We recommend replacement at the factory. Afterwards, all media-contacting gaskets and the glass pads are replaced and a tightness test at 1.5 times the nominal pressure is carried out.

Yes, with the appropriate material combination. Order a material test certificate W10 according to AD 2000 for housing and cover flanges for this. For temperatures ≥ −60 °C, screws A2-70 must be used. We will coordinate the gasket with you.

Medium, nominal size, operating and design pressure, operating and design temperature, connection standard, if applicable vacuum requirement and desired accessories.

Portrait von Dirk Göttgens
Portrait von Dirk Göttgens

Would you like personal advice?

Benefit from our expert knowledge in process monitoring. Our experienced team will provide you with sound advice when selecting the ideal sight glass fittings for your specific requirements. Schedule your personal consultation now!
Search... Your entries are invalid! Please contact us! Possible working pressure: Required thickness: Maximum temperature: This is a standard sight glass that we would be happy to manufacture for you. This is a sight glass according to DIN This is a sight glass according to DIN , which we would be happy to manufacture for you.