Two valve fluid level indicators of type 460 arranged side by side with threaded connections and each with and without impact protection jacket.
A metallic valve assembly with a clear tube section and adjustable knobs on both ends.
A metallic gas valve assembly with two control knobs and a transparent section for monitoring flow.
Stainless steel pipe assembly with valves on both ends and a transparent section in the middle.
Video | Glasrohr Füllstandsanzeiger type 460 - PN25 - made of AISI 316Ti – ACI Industriearmaturen GmbH

Valve fluid level indicator type 460

Valve fluid level indicator with threaded or flange connection

Google reviews for aci24.com
Delivery time on request

Valve liquid level indicator for working pressures up to max. 25 barg 

Certified quality
Technical data
  • 15
  • 20
  • ½“
  • ¾“
  • 25
  • 80°C
  • 130°C
  • 150°C
  • 175°C
  • 180°C
  • 200°C
  • Impact protection tube made of Plexiglas®

Quick overview

max. 25 barg
heat resistant up to 200 °C
for liquid media
Nominal sizes
1/2" - 3/4"
DN 15 - DN 20

Cross-section
drawing

Diagram of two vertical piping systems with labeled dimensions (L1, L2, L3, G, A).
Dimensions
A

G 1/2"

G 3/4"

DN 15

DN 20

L1 63 96 85.5 108
L2 98 98 98 98
L3 65 62 65 76
LV 93.5 95 94 97
LH 119 122 119 122
G 13 16 13 20
PS max (barg) 25 25 25 20

Product information

The ACI valve liquid level indicator type 460 consists of two valves that are connected by a borosilicate glass tube.

It is designed for external mounting on a tank and reliably indicates the liquid level inside the container according to the principle of communicating vessels.

Type 460 is available in freely selectable lengths and can optionally be supplied with threaded or flanged connections. If the center distance between the valve axes exceeds 1500 mm, the pipe is divided into several sections that are stably connected together using spacers.

A stuffing box seal made of PTFE inside the valves ensures a secure seal. In case of contamination or damage, the valve liquid level indicator can be safely disconnected from the container and emptied at the connection points using the integrated shut-off valves.

Due to the sensitive glass tube, type 460 is delivered unassembled. When assembling – especially with flange connections – care must be taken to ensure that the connections are precisely aligned and not twisted against each other to ensure stress-free installation of the glass tube.

To protect the glass tube from mechanical impacts during operation, an impact protection tube made of Plexiglas® is optionally available.

Produktbild
Portrait von Wolfgang Tackenberg
Portrait von Wolfgang Tackenberg

Would you like personal advice?

Benefit from our expert knowledge in process monitoring. Our experienced team will provide you with sound advice when selecting the ideal sight glass fittings for your specific requirements. Schedule your personal consultation now!
Wolfgang Tackenberg
Technical Sales Manager
Go to contact form
Search... Your entries are invalid! Please contact us! Possible working pressure: Required thickness: Maximum temperature: This is a standard sight glass that we would be happy to manufacture for you. This is a sight glass according to DIN This is a sight glass according to DIN , which we would be happy to manufacture for you.